Fluke 3000 FC General Maintenance System | Valley Instrument Service

Fluke 3000 FC General Maintenance System

Connect the FC Wireless iFlex AC Current Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Or connect the FC Wireless AC Voltage Module and view both voltage and current measurements simultaneously. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements.

From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the Fluke Connect remote modules capture up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter.

Description

The Fluke 3000 FC General Maintenance System provides measurement of all common electrical parameters

The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect app has all the essentials for convenient test and measurement troubleshooting:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke v3000 FC Wireless AC Voltage Module offers:

  • Measurements up to 1000 V true-RMS AC
  • Use as a standalone meter or as part of the system
  • A logging function for recording and saving up to 65,000 readings

The Fluke v3001 FC Wireless DC Voltage Module lets you:

  • Measure up to 1000 V DC
  • Use as a standalone meter or as part of the system
  • Use the logging function for recording and saving up to 65,000 readings

The Fluke a3001 FC Wireless iFlex AC Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier:

  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function

  • * For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).

    Detailed Specifications
    AC Voltage
    Range ¹ / Resolution 600.0 mV / 0.1 mV
    6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    DC Voltage, Continuity, Resistance, Diode Test and Capacitance
    Function
    mV Range / Resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 2
    V Range / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 0.09% + 2
    0.15% + 2
    ))) Range / Resolution 600 Ω / 1 Ω
    Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
    Ω Range / Resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    60.00 kΩ / 0.1 kΩ
    600.0 kΩ / 0.001 MΩ
    50.00 MΩ / 0.01 MΩ
    Accuracy 0.5% + 2
    0.5% + 1
    1.5% + 3
    Diode test Range / Resolution 2.000 V / 0.001 V
    Accuracy 1% + 2
    µF Range / Resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF1 / 1 μF
    Accuracy 1.2% + 2
    10% typical
    1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
    AC and DC Current
    Function
    mA AC
    (45 Hz to 1 kHz)
    Range 1 / Resolution 60.00 mA / 0.01 mA
    400.0 mA 3/ 0.1 mA
    Accuracy 1.5% + 3
    mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA
    400.0 mA 3/ 0.1 mA
    Accuracy 0.5% + 3
    1. All AC current ranges are specified from 5% of range to 100% of range.
    2. Input burden voltage (typical): 400 mA input 2 mV/mA.
    3. 400.0 mA accuracy specified up to 600 mA overload.
    Frequency
    Range / Resolution 99.99 Hz / 0.01 Hz
    999.9 Hz / 0.1 Hz
    9.999 kHz / 0.001 kHz
    99.99 kHz / 0.01 kHz
    Accuracy 1 0.1% + 1
    1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
    Input Characteristics
    Function Overload
    protection
    Input impedance
    (nominal)
    Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
    1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
    1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
    Open circuit test voltage Full scale voltage Typical short circuit current
    To 6 MΩ 50 MΩ Typical short circuit current
    1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
    1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
    mA Function
    Overload protection Fused, 44/100 A, 1000 V FAST Fuse
    Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
    MIN/MAX Recording Accuracy
    DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
    AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
    General Specifications
    Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
    Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
    Display (LCD) Update rate 4/sec
    Volts, amps, ohms 6000 counts
    Frequency 10,000 counts
    Capacitance 1,000 counts
    Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
    Battery life 250 hours minimum
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
    Temperature Operating -10°C to 50°C
    Storage -40°C to 60°C
    Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C)
    0% to 75% (35°C to 40°C)
    0% to 45% (40°C to 50°C)
    Altitude Operating 2,000 m
    Storage 12,000 m
    Electromagnetic compatibility
    EMI, RFI, EMC, RF
    EN 61326-1:2006, EN 61326-2-2:2006
    ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
    V1.8.1:2008,
    FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
    FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
    Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
    CAN/CSA-C22.2 No 61010-1-12: 3rd edition
    UL 61010-1: 3rd edition
    IEC/EN 61010-1:2010
    Certifications CSA, FCC, CE
    Ingress Protection (IP) rating IP54
    Pollution Degree 2
    Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
    Weight 340 g (12 oz)
    Not compatible with Fluke CNX test tools

    Fluke v3000 FC Wireless AC Voltage Module

    Accuracy is specified as ±([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5% to 100% of the range obtained by autoranging, from 18°C to 28°C.

    Specifications
    Range ¹ / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    1000 V / 1 V
    Accuracy 2 3 4 45 Hz to 500 Hz 1.0% + 3
    500 Hz to 1 kHz 2.0% + 3
    1. All AC voltage ranges are specified from 1% of range to 100% of range.
    2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
    3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
    4. Do not exceed 107 V-Hz.
    General Specifications
    LCD w/ backlight 3½ digits, 6000 counts, updates 4/sec
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 Hours
    Memory Record up to 65000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient 0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C, 45% at 40°C, 45% at 50°C
    Altitude Operating 2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance ANSI/ISA 61010-1 / (82.02.01) 3rd edition
    CAN/CSA-C22.2 No 61010-1-12 3rd edition
    UL 61010-1 3rd edition
    IEC/EN 61010-1 2010
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution Degree 2
    Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight .22 kg (8 oz)
    Not compatible with Fluke CNX test tools

    Fluke v3001 FC Wireless DC Voltage Module

    Accuracy is specified for 1 year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading ] + [ Number of least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18°C to 28°C.

    Voltage Specifications
    Function
    mVDC Range ¹ / Resolution 600.0 mV / 0.1 mV
    Accuracy 0.09% + 3
    VDC Range ¹ / Resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 0.09% + 3
    Range ¹ / Resolution 1000 V / 1 V
    Accuracy 0.15% + 2
    General Specifications
    LCD w/backlight 3 ½ digits, 6000 counts, 4/sec update rate
    Battery type 2 AA Alkaline batteries, NEDA 15A, IEC LR6
    Log rate/interval Adjustable by PC from 1 sec to 1 hr, default 1 min
    Battery life 400 hours minimum
    Memory Record up to 65,000 readings
    RF communications 2.4 GHz ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient 0.1 x (specified accuracy)/ °C (< 18°C or > 28°C)
    Relative humidity 0% to 90% (0°C to 35°C), 0% to 75% (35°C to 40°C),
    0% to 45% (40°C to 50°C)
    EMC IEC 61236-1, Portable
    Safety compliance IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Size (H x W x D) 160 x 66 x 38 mm (6.3 x 2.6 x 1.5 in)
    Weight 0.255 kg (9 oz)
    Not compatible with Fluke CNX test tools

    Fluke a3001 FC Wireless iFlex AC Current Module

    Specifications
    Range 0.5 A to 2500 A AC
    Resolution 0.1 A
    Accuracy 3% ±5 digits (5 Hz to 500 Hz)
    Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
    2.5 at 1400 A
    1.42 at 2500 A
    add 2% for C.F. > 2
    LCD w/ backlight 3½ digits
    Log rate/interval 1 sec minimum/adjustable by PC or front panel
    Battery type 2 AA, NEDA 15 A, IEC LR6
    Battery life 400 hours
    Memory Record up to 65,000 readings
    RF communications 2.4 GHZ ISM Band
    RF communication range Open air, unobstructed Up to 20 m
    Obstructed, sheetrock wall Up to 6.5 m
    Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
    Operating temperature -10°C to +50°C
    Storage temperature -40°C to +60°C
    Temperature coefficient Add 0.1 x (specified accuracy) /°C (< 18°C or > 28°C)
    Operating humidity 90% at 35°C
    75% at 40°C
    45% at 50°C
    Altitude Operating 2,000 m
    Storage 12,000 m
    EMC EN 61326-1:2006
    Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
    Safety rating CAT IV 600 V, CAT III 1000 V
    Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
    Ingress Protection (IP) rating IP42
    Pollution Degree 2
    Jaw opening 25.4 cm (10 in) coil
    Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
    Weight .22 kg (8 oz)
    Not compatible with Fluke CNX test tools